Established for 28 years, Elitech has grown from a small hardware company to a global leader in the cold chain industry. Elitech is committed to serving global customers and providing high-quality refrigeration products and advanced monitoring services. Elitech's products are designed to save time and resources while protecting the environment and human health, thereby adding value to products and services.

LD-100 Heated Diode Refrigerant Leak Detector

litech LD-100 heated diode refrigerant leak detector offers great sensitivity (3g/yr) and short response time (<3s). It will respond to all halogenated (including Chlorine of Fluorine) refrigerants. This is achieved through the employment of a high sensitive heated diode sensor combined with a sophisticated microprocessor-controlled circuit. In addition to the supreme performance and functional advantages, it is economic and user friendly.

Maintenance

Proper maintenance is important and may extend the service life and improve the performance of your detector.

Warning: Turn the power off before cleaning the body of the device.

Keep the sensor tip clean: Use a cotton cloth or dry air to clean the shield on the sensor tip if it gets contaminated. If the sensor tip itself is contaminated, soak the tip in absolute alcohol for a few minutes, and then use compressed air to dry it, or dry it with a cloth.

Note: Never use strong solvents such as Gasoline, mineral oil, turpentine, these solvents may coat the sensor with a thin film and reduce the sensitivity of the detector and make the detector slow in respond to a leakage.

Put the detector and the sensor in a dry and clean place and remove the batteries if the detector is not used for a long time.

Sensor type: Heated Diode sensor

Minimum Sensitivity: 3g/yr

Response time:<3s

Warm-up time:<60s

Ambient Environment:Temperature: 0℃~50℃; Humidity: < 80%RH(non
condensing)

Display method: Highlight LED display

One-touch reset and six-level adjustable sensitivity

The true mechanical pump provides instant response and clearing

Battery level indication

Sensor failure indication

Three 1.5V AA high-energy battery

Unique shape design

Flexible stainless probe

Application of refrigerant

It will respond to all halogenated (including Chlorine of Fluorine)
refrigerants. This includes, but is not limited to:

CFCs e.g.R12,R11,R500,R503 etc…

HCFCs e.g.R22,R123,R124,R502 etc…

HFCs e.g.R134a,R404a,R410A,R407C etc…

CH R600a

Please fill in your requirements and we will contact you as soon as possible.